Honeywell Humidifier HCM 2051 User Manual

OWNER’S MANUAL  
4 GALLON OUTPUT PER DAY  
COOL MOISTURE HUMIDIFIER  
Model HCM-2051 Series  
* Output dependent on room temperature and humidity.  
 
INTRODUCTION  
®
Thank you for purchasing a Honeywell Natural Cool Moisture Humidifier. If you would like  
more information on our full line of products please visit our website at:  
H O W D O E S I T W O R K ?  
®
NATURAL COOL MOISTURE SYSTEM  
®
Dry air is pulled through the Natural Cool Moisture system and a quiet fan blows out  
invisible, moisture-balanced air. Unwanted minerals and bacteria from the water are trapped  
®
inside the Natural Cool Moisture filter. When the unit is running you will not see or feel a  
mist. You will know your humidifier is putting moisture into the air as you watch the water  
level in your tank decrease throughout the day.  
W H AT I S A g I O N A N T I M I C R O B I A L  
?
®
Your Honeywell Natural Cool Moisture filter has been designed using new AgION™  
technology which prevents surface growth and migration of mold, fungus, algae and bacteria  
in the filter for its life - approximately one season. Keep in mind, depending on your water  
quality, mineral deposits can still clog or discolor the filter, affect its life and that of the  
humidifier.  
M O D E L - H C M - 2 0 5 1  
Your humidifier is made up of these parts:  
Water Tank  
Motor Housing  
Natural Cool  
Fill Cap  
®
Moisture Filter  
Base  
 
SET UP  
NOTE: We recommend that the humidifier be disinfected prior to first use. Please  
see CLEANING instructions.  
Select a firm, level, flat location - at least six inches from any wall for proper air flow (Fig.  
1). Place the humidifier on a water-resistant surface, as water can damage furniture and  
some flooring.  
The manufacturer will not accept responsibility for property damage caused by water  
spillage  
FILLING  
Remove the water tank by grasping handle and  
pulling straight up (Fig. 1). Set aside.  
Fig. 1  
Lift up on the motor housing to remove and set aside  
®
(Fig. 2). Remove the Natural Cool Moisture filter  
from the base before filling the unit with water. Soak  
filter in a sink full of cool water to help reduce  
mineral build up and place back in the humidifier  
6"  
while wet. DO NOT SQUEEZE OR WRING OUT THE  
®
NATURAL COOL MOISTURE FILTER. To help extend  
the life of your filter repeat this step each time you  
fill your humidifier.  
Fig. 2  
Turn the Water Tank upside down so that the Fill Cap  
is facing up; unscrew the Fill Cap by turning it  
counter-clockwise  
and set aside.  
Fill the Water Tank with COOL tap water (Fig. 3).  
Distilled water is not necessary as the water is filtered  
®
by the Natural Cool Moisture filter. DO NOT USE HOT  
WATER. Doing so may damage the humidifier.  
Fig. 3  
Replace the fill cap by turning it clockwise  
. DO  
NOT OVER TIGHTEN. Turn the Water Tank right-side  
up.  
NOTE: WHEN CARRYING THE FILLED WATER TANK  
PLEASE USE THE HANDLE AND PLACE YOUR OTHER  
HAND UNDER THE TANK FOR ADDITIONAL SUPPORT.  
 
FILLING CONTINUED  
Place the Motor Housing back into the base.  
Position the Water Tank in the humidifier and push into place. Some water will empty into  
the base.  
Once the filled tank has been positioned, do not attempt to move the humidifier. If it has to  
be moved, unplug the humidifier and remove the water tank first.  
CAUTION: DO NOT POUR WATER INTO THE GRILLE ON TOP OF THE HUMIDIFIER.  
DOING SO MAY DAMAGE THE HUMIDIFIER OR CAUSE PERSONAL INJURY.  
OPERATION  
P O W E R  
CAUTION: DO NOT PLUG IN THE HUMIDIFIER WITH WET HANDS AS AN  
ELECTRICAL SHOCK COULD OCCUR.  
With the power switch in the OFF position, plug the filled humidifier into a  
polarized 120V outlet. DO NOT FORCE THE POLARIZED PLUG INTO THE OUTLET; it  
will only fit one way.  
Fig. 4  
H U M I D I T Y C O N T R O L  
1. Set the fan speed to the desired position (Fig. 4).  
HIGH: For fast humidifying  
MED: For everyday moisture control  
LOW: For quieter nighttime operation  
2. Set the Moisture Control knob (Humidistat) to the  
highest setting by turning the dial clockwise  
No. 9 (Fig. 4).  
to  
NOTE: If the humidifier fan will not start or restart  
when you select a fan speed, the Moisture Control  
may be set too low. Turn the dial clockwise  
to No.9. This is the highest setting. The Desired  
Humidity light will be Off when the unit is  
producing moisture (Fig. 4).  
Turn the humidifier OFF if the humidity level feels too moist or you notice  
condensation forming on the walls and/or windows.  
 
FEATURES  
M O I S T U R E C O N T R O L K N O B / H U M I D I S TAT  
The Moisture Control Knob allows you to adjust and select the humidity level to your personal  
preference. Your humidifier will turn on and off throughout the day and night to maintain the  
desired humidity level you have selected.  
H O W T O S E T T H E M O I S T U R E C O N T R O L K N O B / H U M I D I S TAT  
First run the humidifier per the operation instruction with the Moisture Control knob set to No.  
9the highest setting.  
Let the humidifier run on high for a least one hour or until your room has reached a  
comfortable humidity level.  
Fig.5  
At this point, slowly turn your Moisture Control knob  
counter-clockwise  
until the humidifier shuts off  
and the Desired Humidity light comes on (Fig. 5).  
Now that your Moisture Control knob is set, the  
humidifier will automatically turn back on when your  
room drops below your comfort setting and will  
automatically turn off again when the setting is  
reached.  
AUTOMATIC SHUT OFF FEATURE - REFILL LIGHT  
1. AUTO-OFF  
The humidifier will turn off when both the Base and Water Tank are empty. The Refill light  
will glow to let you know your humidifier is empty.  
2. AUTO-ON  
Refill the tank per the FILLING instructions. Once the base begins to fill with water the Refill  
light will go off and the unit will automatically turn back on.  
 
WEEKLY CLEANING  
We recommend cleaning the humidifier once a week, more often if you have hard water,  
notice a build up of impurities or detect unpleasant odors.  
Cleaning involves two steps SCALE REMOVAL and DISINFECTING. Be sure to perform these  
in the proper order to avoid harmful chemical interactions.  
First, turn off and unplug the humidifier.  
Remove the Water Tank and Motor Housing.  
®
Remove the Natural Cool Moisture filter from the Base.  
Empty any water from the Base.  
NOTE: REMOVE FILTER BEFORE CLEANING.  
Failure to remove filter during cleaning will destroy the filter.  
STEP ONE:  
STEP TWO:  
SCALE REMOVAL  
DISINFECTING  
BASE  
WATER TANK/BASE  
1. Fill the Base with either:  
1. Fill the Water Tank with:  
1 teaspoon of household bleach  
and  
1 cup (8 oz) of undiluted white  
vinegar  
or  
1 gallon of water  
Pour some of this solution into the  
Base.  
®
Use DuraRinse Humidifier  
Cleaner, part no. AC-816, following  
the instructions on the bottle.  
2. Let solution stand for 20 minutes.  
2. Let solution stand for 20 minutes.  
3. Rinse with water until the odor of  
bleach is gone.  
®
3. With the vinegar or DuraRinse in the  
Base clean all interior surfaces with a  
soft cloth or brush to help remove scale.  
4. Rinse the Base thoroughly with water  
to remove scale and cleaning solution.  
NOTE: THE USE OF OTHER WATER TREATMENT PRODUCTS AND CHEMICALS MAY  
CAUSE DETERIORATION OF THE FILTER OR DAMAGE THE HUMIDIFIER, THEREBY  
HINDERING THE HUMIDIFIERS EFFECTIVENESS.  
 
PROLONGING THE LIFE OF THE FILTER AND  
MAINTAINING A CLEAN HUMIDIFER  
®
NOTE: DO NOT ATTEMPT TO CLEAN THE NATURAL COOL MOISTURE FILTER WITH ANY  
CHEMICAL SOLUTIONS, DOING SO WILL DAMAGE THE FILTER.  
AgIONprevents the surface growth and migration of mold, fungus, algae, and bacteria.  
It is normal for a filter to discolor from mineral build-up. This will vary depending on water  
quality.  
DO NOT clean the filter using any chemical solution.  
®
If a Natural Cool Moisture filter appears to be clogged by hard water or mineral deposits,  
soak it in a sink full of cool water for 10 minutes. DO NOT SQUEEZE OR WRING OUT THE  
®
NATURAL COOL MOISTURE FILTER. Always place filter back in the humidifier wet.  
®
To prevent mineral deposits use DuraFree Humidifier Water Softener, part no. AC-817,  
each time the Water Tank is refilled.  
®
Always purchase Honeywell Brand Natural Cool Moisture filters as the fan motor of this  
®
humidifier and the Natural Cool Moisture filter are designed to function efficiently as a  
set. Using any other filter could damage the motor or reduce the humidifiers  
performance.  
Be sure to empty water from the Water Tank and Base when not in use.  
END-OF-THE-SEASON CARE AND STORAGE  
Follow weekly CLEANING instructions when the humidifier will not be used for at least one  
week or more, or at the end of the season.  
At the end of the season, remove and throw away the filter; do not store with a used filter.  
Dry the humidifier completely before storing. DO NOT store with water inside the Base or  
Water Tank.  
Pack the unit in its original carton and store in a cool, dry location.  
Before next use, remember to install a new filter and clean the humidifier.  
 
TROUBLE SHOOTING  
Q: I hear the fan turning, but I dont see any mist. Is my humidifier operating  
properly?  
®
A: Dry air is pulled through the Natural Cool Moisture system and a fan disperses invisible,  
moisture balanced air. There is no mistemitted. When operating normally you will feel  
only cool air coming from the unit. Monitor the water level in your Tank/ Base. If you  
notice a decrease in the Water Tank over 24 hours then the unit is operating normally.  
Q: My unit has been running for several hours. I hear the fan spinning, but I do not notice  
the water level in the tank decreasing.  
®
A: First, check the Natural Cool Moisture filter to ensure it is wet. If the pad appears dry,  
remove it from the Base and gently rinse under cool water. Reposition wet filter in the  
Base. You may also want to note the current moisture level in your home. If the humidity  
level is over 60% the unit will not put out much moisture as your air is already saturated.  
Q: The humidifier is not running (the fan is not even spinning), but all (or some) of the lights  
are on.  
A: If the Desired Humidity light is ON: The Moisture Control knob may be set too low. Moving  
the Moisture Control knob to No. 9 should restart the unit.  
If the Refill light is ON: The humidifier is out of water. Refill the Water Tank and the  
humidifier should restart.  
Q: The Moisture Control knob was set according to the manual, but the humidifier never  
seems to turn back on. Is something wrong?  
A: The Moisture Control knob may be set too low. Moving the Moisture Control knob to No. 9  
should restart the unit. Reset the Moisture Control knob following the instructions under  
FEATURES.  
Q: The Moisture Control knob was set according to the manual, but the humidifier never  
seems to turn off. Is something wrong?  
A: The Moisture Control knob may be set too high. Reset the Moisture Control knob following  
the instructions under FEATURES.  
Q: My filter has changed color. Do I need a new filter?  
A: Probably not. Since your filter has been made with AgIONtechnology the change in  
color indicates only a mineral deposit. Soak filter in a sink full of cool water to help break  
up deposits. The discoloration may remain but will not affect the humidifiers  
performance.  
 
CARE PRODUCTS  
If your local retailer is out of stock, Honeywell replacement parts and care products may be  
ordered directly from the manufacturer. You can call 1-800-332-1110 to order with a MasterCard,  
Visa or Discover or fill out the form below and mail it along with a check or money order (sorry no  
CODs accepted) to:  
Honeywell  
Consumer Service Center  
250 Turnpike Road  
Southborough, MA 01772  
Please allow four to six weeks for delivery.  
Massachusetts residents please add 5% Sales Tax.  
Item  
Item No.  
Qty.  
U.S. Price  
Total  
®
Natural Cool Moisture Filter, one per pack  
HAC-504  
AC-817  
$ 14.00  
5.00  
®
DuraFree Humidifier Water Softener (32 oz.)  
®
DuraRinse Humidifier Cleaner (32 oz.)  
AC-816  
5.00  
Water Tank and Fill Cap  
Fill Cap  
HCM-2051-1  
19.99  
HCM-2051-2  
9.99  
SUBTOTAL  
MA Residents add 5% Sales Tax  
Shipping and Handling  
TOTAL ENCLOSED  
$4.95  
Name  
Check or Money Order Enclosed  
Credit Card No.  
Exp. Date  
Address  
Day Time Phone  
Signature  
 
ELECTRICAL RATINGS  
Model HCM-2051 is rated 0.6 Amps at 120V, 60 Hz.  
NOTE: IF YOU EXPERIENCE A PROBLEM WITH YOUR HUMIDIFIERS POWER UNIT, PLEASE  
SEE THE WARRANTY FOR INSTRUCTIONS. PLEASE DO NOT ATTEMPT TO OPEN OR REPAIR  
THE HUMIDIFIER YOURSELF. DOING SO WILL VOID THE WARRANTY AND COULD CAUSE  
DAMAGE OR PERSONAL INJURY. IF THE PROBLEM PERSISTS, PLEASE CONTACT THE  
CONSUMER SERVICE CENTER.  
CUSTOMER ASSISTANCE  
Mail questions or comments to:  
Honeywell  
Consumer Service Center  
250 Turnpike Road  
Southborough, MA 01772  
Please be sure to specify model number.  
Call us toll-free at:  
1-800-332-1110  
Or visit our website at:  
 
5 YEAR LIMITED WARRANTY  
You should first read all instructions before  
attempting to use this product.  
should be returned to the place of purchase in  
accordance with store policy. Thereafter,  
while within the warranty period defective  
product may be returned to Honeywell.  
The enclosed Customer Response card should  
be filled out and returned within 7 days of  
purchase.  
C. This warranty does not cover damage  
resulting from any unauthorized attempts to  
repair or from any use not in accordance with  
the instruction manual.  
A. This 5 year limited warranty applies to repair  
or replacement of product found to be  
defective in material or workmanship. This  
warranty does not apply to damage resulting  
from commercial, abusive, unreasonable use  
or supplemental damage. Defects that are the  
result of normal wear and tear will not be  
considered manufacturing defects under this  
warranty.  
HONEYWELL IS NOT LIABLE FOR INCIDENTAL  
OR CONSEQUENTIAL DAMAGES OF ANY  
NATURE. ANY IMPLIED WARRANTY OF  
MERCHANTABILITY FOR FITNESS FOR A  
PARTICULAR PURPOSE ON THIS PRODUCT IS  
LIMITED IN DURATION TO THE DURATION OF  
THIS WARRANTY.  
NOTE: THIS WARRANTY DOES NOT COVER THE  
®
NATURAL COOL MOISTURE FILTER, WHOSE  
PERFORMANCE WILL DEPEND UPON THE  
CONDITION OF THE WATER USED IN THE  
HUMIDIFIER.  
D. Return defective product to Honeywell  
Consumer Products with a brief description of  
the problem. Include proof of purchase and a  
$10 US check or money order for handling,  
return packing and shipping charges. Please  
include your name, address and a daytime  
phone number.  
You must prepay shipping charges.  
Some jurisdictions do not allow the exclusion  
or limitation of incidental or consequential  
damages or limitations on how long an implied  
warranty lasts, so the above limitations or  
exclusions may not apply to you. This  
warranty gives you specific legal rights, and  
you also may have other rights which vary  
from jurisdiction to jurisdiction. This warranty  
applies only to the original purchaser of this  
product from the original date of purchase.  
Send to:  
Honeywell  
Consumer Products,  
Attn: Returns Department,  
4755 South Point Drive, Memphis, TN 38118  
1-800-332-1110  
B. At its option, Honeywell will repair or replace  
this product if it is found to be defective in  
material or workmanship. Defective product  
©2001 All rights reserved. Honeywell  
69-3006  
P/N: 035-02383-000  
 

Greenheck Fan Ventilation Hood 468502 User Manual
Halo Lighting System Indoor Furnishings LZR311 User Manual
Hans Grohe Indoor Furnishings 37200XX1 User Manual
Hearth and Home Technologies Indoor Fireplace 350TRS CE User Manual
Hearth and Home Technologies Stove 3500L User Manual
Heath Zenith Home Safety Product 52 4075 User Manual
Honeywell Fan HV 141 User Manual
HP Hewlett Packard Computer Accessories 370971 004 User Manual
HP Hewlett Packard Server AA RTDRB TE User Manual
Husky Nail Gun HDN23200 User Manual